Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
38.0 %
62.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_diesel
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
38.0 %
62.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_diesel

Details

Sector energy
Use energetic
Merit Order
level
hv
subtype
dispatchable
type
producer
Node groups
  1. preset_demand
  2. central_production
  3. electricity_production
  4. dispatchable_production
  5. hv_net_supply
  6. wacc_proven_tech
  7. costs_production_power_plants
  8. sankey_conversion_group
Used in Gqueries
  1. diesel_distribution_to_energy_in_sankey
  2. diesel_engine_capacity_in_power_plant_economic_performance_table
  3. diesel_engine_capex_in_power_plant_economic_performance_table
  4. diesel_engine_full_load_hours_in_power_plant_economic_performance_table
  5. diesel_engine_opex_in_power_plant_economic_performance_table
  6. diesel_engine_position_in_power_plant_economic_performance_table
  7. diesel_engine_profit_in_power_plant_economic_performance_table
  8. diesel_engine_revenue_in_power_plant_economic_performance_table
  9. energy_oil_total_in_co2_sankey
  10. energy_power_engine_diesel
  11. energy_power_engine_diesel_delta_in_investment_cost_table
  12. energy_power_engine_diesel_future_in_investment_cost_table
  13. energy_power_engine_diesel_present_in_investment_cost_table
  14. merit_order_diesel_engine_availability_in_merit_order_table
  15. merit_order_diesel_engine_capacity_in_merit_order_table
  16. merit_order_diesel_engine_full_load_hours_in_merit_order_table
  17. merit_order_diesel_engine_load_factor_in_merit_order_table
  18. merit_order_diesel_engine_operating_costs_in_merit_order_table
  19. merit_order_diesel_engine_position_in_merit_order_table
  20. total_cost_of_energy_power_engine_diesel
Used in Inputs
  1. capacity_of_energy_power_engine_diesel
  2. efficiency_energy_power_engine_diesel
  3. investment_costs_combustion_oil_plant
  4. om_costs_combustion_oil_plant
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 38.0 38.0 %
full_load_hours Full load hours 4,000 0 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 200000 200000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 0 0 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 15 15 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 30 30 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 22{:class=>"change"}MWe
heat_output_capacity 00{:class=>"change"}MWth
hydrogen_output_capacity 00{:class=>"change"}MW
free_co2_factor 00{:class=>"change"}
ccs_capture_rate --{:class=>"change"}
construction_time 11{:class=>"change"}
electrical_efficiency_when_using_coal --{:class=>"change"}
electrical_efficiency_when_using_wood_pellets --{:class=>"change"}
full_load_hours 4,0000{:class=>"change"}
households_supplied_per_unit --{:class=>"change"}
land_use_per_unit 00{:class=>"change"}
takes_part_in_ets 00{:class=>"change"}yes=1 / no=0
technical_lifetime 3030{:class=>"change"}year
typical_input_capacity --{:class=>"change"}MWinput
output_capacity --{:class=>"change"}MW
input_efficiency --{:class=>"change"}
output_efficiency --{:class=>"change"}
cost
initial_investment 400 K400 K{:class=>"change"}euro / unit
ccs_investment 00{:class=>"change"}euro / unit
cost_of_installing 00{:class=>"change"}euro / unit
decommissioning_costs 00{:class=>"change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 00{:class=>"change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 15.715.7{:class=>"change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{:class=>"change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{:class=>"change"}euro / MWinput
costs_per_mj --{:class=>"change"}
wacc 0.040.04{:class=>"change"}
profitability -unprofitable{:class=>"change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{:class=>"change"}eur/MWh
marginal_costs 152152{:class=>"change"}euro / MWh
max_consumption_price 152152{:class=>"change"}euro / MWh
capital_expenditures 21,60021,600{:class=>"change"}euro / unit / year
operating_expenses 62,8000{:class=>"change"}euro / unit / year
operating_expenses_including_fuel 1,216 K0{:class=>"change"}euro / unit / year
revenue 00{:class=>"change"}euro / unit / year
merit_order
merit_order_full_load_hours --{:class=>"change"}
merit_order_capacity_factor --{:class=>"change"}
merit_order_position --{:class=>"change"}
security_of_supply
availability 0.950.95{:class=>"change"}
part_load_operating_point --{:class=>"change"}
part_load_efficiency_penalty --{:class=>"change"}
forecasting_error --{:class=>"change"}
misc
demand_expected_value --{:class=>"change"}
excel_id --{:class=>"change"}
max_demand --{:class=>"change"}
Node Calculations Present Future Change Unit
demand
demand 00{:class=>"change"}
preset_demand 00{:class=>"change"}
demand_of_sustainable 00{:class=>"change"}
weighted_carrier_cost_per_mj 0.0150.015{:class=>"change"}
weighted_carrier_co2_per_mj 0.0740.074{:class=>"change"}
sustainability_share 00{:class=>"change"}
final_demand 00{:class=>"change"}
primary_demand 00{:class=>"change"}
primary_demand_of_fossil 00{:class=>"change"}
primary_demand_of_sustainable 00{:class=>"change"}
technical
input_capacity 5.265.26{:class=>"change"}
electric_based_input_capacity 5.265.26{:class=>"change"}MWinput
heat_based_input_capacity --{:class=>"change"}MWinput
cooling_based_input_capacity --{:class=>"change"}MWinput
number_of_units 00{:class=>"change"}
costs_per_plant
total_costs_per(:plant) 1,238 K21,600{:class=>"change"}euro / plant
fixed_costs_per(:plant) 21,60021,600{:class=>"change"}
cost_of_capital_per(:plant) 8,266.78,266.7{:class=>"change"}
depreciation_costs_per(:plant) 13,333.313,333.3{:class=>"change"}
variable_costs_per(:plant) 1,216 K0{:class=>"change"}
fuel_costs_per(:plant) 1,153 K0{:class=>"change"}
co2_emissions_costs_per(:plant) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:plant) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:plant) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:plant) 62,8000{:class=>"change"}
total_initial_investment_per(:plant) 400 K400 K{:class=>"change"}
costs_per_node
total_costs_per(:node) 00{:class=>"change"}
fixed_costs_per(:node) 00{:class=>"change"}
cost_of_capital_per(:node) 00{:class=>"change"}
depreciation_costs_per(:node) 00{:class=>"change"}
variable_costs_per(:node) 00{:class=>"change"}
fuel_costs_per(:node) 00{:class=>"change"}
co2_emissions_costs_per(:node) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:node) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
total_initial_investment_per(:node) 00{:class=>"change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 619 K10,800{:class=>"change"}
fixed_costs_per(:mw_electricity) 10,80010,800{:class=>"change"}
cost_of_capital_per(:mw_electricity) 4,133.34,133.3{:class=>"change"}
depreciation_costs_per(:mw_electricity) 6,666.76,666.7{:class=>"change"}
variable_costs_per(:mw_electricity) 608 K0{:class=>"change"}
fuel_costs_per(:mw_electricity) 577 K0{:class=>"change"}
co2_emissions_costs_per(:mw_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 31,4000{:class=>"change"}
total_initial_investment_per(:mw_electricity) 200 K200 K{:class=>"change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 154.70{:class=>"change"}
fixed_costs_per(:mwh_electricity) 2.70{:class=>"change"}
cost_of_capital_per(:mwh_electricity) 1.030{:class=>"change"}
depreciation_costs_per(:mwh_electricity) 1.670{:class=>"change"}
variable_costs_per(:mwh_electricity) 152NaN{:class=>"change"}
fuel_costs_per(:mwh_electricity) 144.1NaN{:class=>"change"}
co2_emissions_costs_per(:mwh_electricity) 0NaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 0NaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0NaN{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 7.85NaN{:class=>"change"}
total_initial_investment_per(:mwh_electricity) 500{:class=>"change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 00{:class=>"change"}
fixed_costs_per(:mw_heat) 00{:class=>"change"}
cost_of_capital_per(:mw_heat) 00{:class=>"change"}
depreciation_costs_per(:mw_heat) 00{:class=>"change"}
variable_costs_per(:mw_heat) 0NaN{:class=>"change"}
fuel_costs_per(:mw_heat) 0NaN{:class=>"change"}
co2_emissions_costs_per(:mw_heat) NaNNaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_heat) NaNNaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) NaNNaN{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 0NaN{:class=>"change"}
total_initial_investment_per(:mw_heat) 00{:class=>"change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 00{:class=>"change"}
fixed_costs_per(:mwh_heat) 00{:class=>"change"}
cost_of_capital_per(:mwh_heat) 00{:class=>"change"}
depreciation_costs_per(:mwh_heat) 00{:class=>"change"}
variable_costs_per(:mwh_heat) 0NaN{:class=>"change"}
fuel_costs_per(:mwh_heat) 0NaN{:class=>"change"}
co2_emissions_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 0NaN{:class=>"change"}
total_initial_investment_per(:mwh_heat) 00{:class=>"change"}